CORC  > 厦门大学  > 化学化工-已发表论文
Sensitive ionization of non-volatile analytes using protein solutions as spray liquid in desorption electrospray ionization mass spectrometry
Zhu, Zhiqiang ; Han, Jing ; Zhang, Yan ; Zhou, Yafei ; Xu, Ning ; Zhang, Bo ; Gu, Haiwei ; Chen, Huanwen ; Zhang B(张博)
刊名http://dx.doi.org/10.1002/rcm.6387
2012-12-15
关键词ASSISTED LASER DESORPTION/IONIZATION NUCLEAR-MAGNETIC-RESONANCE AMBIENT CONDITIONS AQUEOUS-SOLUTION MILK-PRODUCTS URINE SAMPLES EESI-MS METABOLOMICS CHROMATOGRAPHY EXPLOSIVES
英文摘要National Natural Science Foundation of China [21175019, 21005015]; State Key Laboratory of Proteomics [SKLP-O201105]; RATIONALE Desorption electrospray ionization (DESI) is the most popular ambient ionization technique for direct analysis of complex samples without sample pretreatment. However, for many applications, especially for trace analysis, it is of interest to improve the sensitivity of DESI-mass spectrometry (MS). METHODS In traditional DESI-MS, a mixture of methanol/water/acetic acid is usually used to generate the primary ions. In this article, dilute protein solutions were electrosprayed in the DESI method to create multiply charged primary ions for the desorption ionization of trace analytes on various surfaces (e.g., filter paper, glass, Al-foil) without any sample pretreatment. The analyte ions were then detected and structurally characterized using a LTQ XL mass spectrometer. RESULTS Compared with the methanol/water/acetic acid (49:49:2, v/v/v) solution, protein solutions significantly increased the signal levels of non-volatile compounds such as benzoic acid, TNT, o-toluidine, peptide and insulin in either positive or negative ion detection mode. For all the analytes tested, the limits of detection (LODs) were reduced to about half of the original values which were obtained using traditional DESI. The results showed that the signal enhancement is highly correlated with the molecular weight of the proteins and the selected solid surfaces. CONCLUSIONS The proposed DESI method is a universal strategy for rapid and sensitive detection of trace amounts of strongly bound and/or non-volatile analytes, including explosives, peptides, and proteins. The results indicate that the sensitivity of DESI can be further improved by selecting larger proteins and appropriate solid surfaces. Copyright (C) 2012 John Wiley & Sons, Ltd.
语种英语
出版者RAPID COMMUN MASS SP
内容类型期刊论文
源URL[http://dspace.xmu.edu.cn/handle/2288/88583]  
专题化学化工-已发表论文
推荐引用方式
GB/T 7714
Zhu, Zhiqiang,Han, Jing,Zhang, Yan,et al. Sensitive ionization of non-volatile analytes using protein solutions as spray liquid in desorption electrospray ionization mass spectrometry[J]. http://dx.doi.org/10.1002/rcm.6387,2012.
APA Zhu, Zhiqiang.,Han, Jing.,Zhang, Yan.,Zhou, Yafei.,Xu, Ning.,...&张博.(2012).Sensitive ionization of non-volatile analytes using protein solutions as spray liquid in desorption electrospray ionization mass spectrometry.http://dx.doi.org/10.1002/rcm.6387.
MLA Zhu, Zhiqiang,et al."Sensitive ionization of non-volatile analytes using protein solutions as spray liquid in desorption electrospray ionization mass spectrometry".http://dx.doi.org/10.1002/rcm.6387 (2012).
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace