Determination of polybrominated diphenyl ethers in river water by combination of liquid–liquid extraction and gas chromatography–mass spectrometry | |
Weifei Zhang ; Xuexia Lin ; Hai-Fang Li ; Zhihua Wang ; Jin-Ming Lin ; Weifei Zhang ; Xuexia Lin ; Hai-Fang Li ; Zhihua Wang ; Jin-Ming Lin | |
2016-03-30 ; 2016-03-30 | |
关键词 | Polybrominated diphenyl ethers Dibromobiphenyl GC–MS Liquid–liquid extraction O657.63 X832 |
其他题名 | Determination of polybrominated diphenyl ethers in river water by combination of liquid–liquid extraction and gas chromatography–mass spectrometry |
中文摘要 | In this work,a reliable and sensitive method for detecting polybrominated diphenyl ethers(PBDEs) has been developed by the combination of liquid–liquid extraction and gas chromatography–mass spectrometry.PBDEs were extracted from a large volume of water by liquid–liquid extraction and purified by silica gel chromatography.In order to reduce the deviation,dibromobiphenyl was exploited as the internal standard to minimize differences among the injections.The quantification was performed using an external standard.Good linear correlation coefficients(>0.991) and a wide linearity range(1.0–500.0 ng/L) indicated the steadiness of the proposed method.Moreover,the satisfactory recovery(>75%)suggested that successful determination of PBDEs in river water had been achieved.Furthermore,the deduction behavior of PBDEs in river water could be inferred according to the results.; In this work,a reliable and sensitive method for detecting polybrominated diphenyl ethers(PBDEs) has been developed by the combination of liquid–liquid extraction and gas chromatography–mass spectrometry.PBDEs were extracted from a large volume of water by liquid–liquid extraction and purified by silica gel chromatography.In order to reduce the deviation,dibromobiphenyl was exploited as the internal standard to minimize differences among the injections.The quantification was performed using an external standard.Good linear correlation coefficients(>0.991) and a wide linearity range(1.0–500.0 ng/L) indicated the steadiness of the proposed method.Moreover,the satisfactory recovery(>75%)suggested that successful determination of PBDEs in river water had been achieved.Furthermore,the deduction behavior of PBDEs in river water could be inferred according to the results. |
语种 | 英语 ; 英语 |
内容类型 | 期刊论文 |
源URL | [http://ir.lib.tsinghua.edu.cn/ir/item.do?handle=123456789/145927] |
专题 | 清华大学 |
推荐引用方式 GB/T 7714 | Weifei Zhang,Xuexia Lin,Hai-Fang Li,et al. Determination of polybrominated diphenyl ethers in river water by combination of liquid–liquid extraction and gas chromatography–mass spectrometry[J],2016, 2016. |
APA | Weifei Zhang.,Xuexia Lin.,Hai-Fang Li.,Zhihua Wang.,Jin-Ming Lin.,...&Jin-Ming Lin.(2016).Determination of polybrominated diphenyl ethers in river water by combination of liquid–liquid extraction and gas chromatography–mass spectrometry.. |
MLA | Weifei Zhang,et al."Determination of polybrominated diphenyl ethers in river water by combination of liquid–liquid extraction and gas chromatography–mass spectrometry".(2016). |
个性服务 |
查看访问统计 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论