Virtual flux in a three-level pulse width modulation rectifier | |
Zhang Yingchao ; Zhao Zhengming ; Zhang Yongchang ; Lu Ting ; Yuan Liqiang | |
2010-10-12 ; 2010-10-12 | |
关键词 | Experimental/ power control PWM rectifiers/ virtual flux three-level pulse width modulation rectifier sensorless control surge currents/ B1210 Power electronics, supply and supervisory circuits |
中文摘要 | Sensorless control gives higher reliability and economic benefits. This paper describes a method to calculate the virtual flux for a three-level pulse width modulation (PWM) rectifier. Then, two control strategies are given for a three-level pulse width modulation rectifier without power source sensors based on the virtual flux. Pre-calculation of the virtual flux and a soft-startup control scheme were used to reduce excessive surge currents during system startup. Experimental results show that the scheme can be easily applied to control a three-level pulse width modulation rectifier without power source voltage sensors, and that the startup current is reduced about 50% by the soft-start process. |
语种 | 中文 |
出版者 | Tsinghua University Press ; China |
内容类型 | 期刊论文 |
源URL | [http://hdl.handle.net/123456789/82577] |
专题 | 清华大学 |
推荐引用方式 GB/T 7714 | Zhang Yingchao,Zhao Zhengming,Zhang Yongchang,et al. Virtual flux in a three-level pulse width modulation rectifier[J],2010, 2010. |
APA | Zhang Yingchao,Zhao Zhengming,Zhang Yongchang,Lu Ting,&Yuan Liqiang.(2010).Virtual flux in a three-level pulse width modulation rectifier.. |
MLA | Zhang Yingchao,et al."Virtual flux in a three-level pulse width modulation rectifier".(2010). |
个性服务 |
查看访问统计 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论