Automated Detection Framework of the Calcified Plaque with Acoustic Shadowing in IVUS Images
Zhifan Gao; Wei Guo; Xin Liu; Wenhua Huang; Heye Zhang; Ning Tan; William Kongto Hau; Yuan-Ting Zhang; Huafeng Liu
刊名PLOS ONE
2014
英文摘要Intravascular Ultrasound (IVUS) is one ultrasonic imaging technology to acquire vascular cross-sectional images for the visualization of the inner vessel structure. This technique has been widely used for the diagnosis and treatment of coronary artery diseases. The detection of the calcified plaque with acoustic shadowing in IVUS images plays a vital role in the quantitative analysis of atheromatous plaques. The conventional method of the calcium detection is manual drawing by the doctors. However, it is very time-consuming, and with high inter-observer and intra-observer variability between different doctors. Therefore, the computer-aided detection of the calcified plaque is highly desired. In this paper, an automated method is proposed to detect the calcified plaque with acoustic shadowing in IVUS images by the Rayleigh mixture model, the Markov random field, the graph searching method and the prior knowledge about the calcified plaque. The performance of our method was evaluated over 996 in-vivo IVUS images acquired from eight patients, and the detected calcified plaques are compared with manually detected calcified plaques by one cardiology doctor. The experimental results are quantitatively analyzed separately by three evaluation methods, the test of the sensitivity and specificity, the linear regression and the Bland-Altman analysis. The first method is used to evaluate the ability to distinguish between IVUS images with and without the calcified plaque, and the latter two methods can respectively measure the correlation and the agreement between our results and manual drawing results for locating the calcified plaque in the IVUS image. High sensitivity (94.68%) and specificity (95.82%), good correlation and agreement (>96.82% results fall within the 95% confidence interval in the Student t-test) demonstrate the effectiveness of the proposed method in the detection of the calcified plaque with acoustic shadowing in IVUS images.
收录类别SCI
原文出处http://www.plosone.org/article/fetchObject.action?uri=info:doi/10.1371/journal.pone.0109997&representation=PDF
语种英语
内容类型期刊论文
源URL[http://ir.siat.ac.cn:8080/handle/172644/5707]  
专题深圳先进技术研究院_医工所
作者单位PLOS ONE
推荐引用方式
GB/T 7714
Zhifan Gao,Wei Guo,Xin Liu,et al. Automated Detection Framework of the Calcified Plaque with Acoustic Shadowing in IVUS Images[J]. PLOS ONE,2014.
APA Zhifan Gao.,Wei Guo.,Xin Liu.,Wenhua Huang.,Heye Zhang.,...&Huafeng Liu.(2014).Automated Detection Framework of the Calcified Plaque with Acoustic Shadowing in IVUS Images.PLOS ONE.
MLA Zhifan Gao,et al."Automated Detection Framework of the Calcified Plaque with Acoustic Shadowing in IVUS Images".PLOS ONE (2014).
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace