Evaluation of electrical capacitance tomography sensor based on the coupling of fluid field and electrostatic field
Ye, Jiamin1; Wang, Haigang1; Yang, Wuqiang2
刊名MEASUREMENT SCIENCE AND TECHNOLOGY
2016-07-01
卷号27期号:7页码:1-13
关键词electrical capacitance tomography sensor structure electrodes coupling simulation sensitivity analysis
英文摘要Electrical capacitance tomography (ECT) is based on capacitance measurements from electrode pairs mounted outside of a pipe or vessel. The structure of ECT sensors is vital to image quality. In this paper, issues with the number of electrodes and the electrode covering ratio for complex liquid-solids flows in a rotating device are investigated based on a new coupling simulation model. The number of electrodes is increased from 4 to 32 while the electrode covering ratio is changed from 0.1 to 0.9. Using the coupling simulation method, real permittivity distributions and the corresponding capacitance data at 0, 0.5, 1, 2, 3, 5, and 8 s with a rotation speed of 96 rotations per minute (rpm) are collected. Linear back projection (LBP) and Landweber iteration algorithms are used for image reconstruction. The quality of reconstructed images is evaluated by correlation coefficient compared with the real permittivity distributions obtained from the coupling simulation. The sensitivity for each sensor is analyzed and compared with the correlation coefficient. The capacitance data with a range of signal-to-noise ratios (SNRs) of 45, 50, 55 and 60 dB are generated to evaluate the effect of data noise on the performance of ECT sensors. Furthermore, the SNRs of experimental data are analyzed for a stationary pipe with permittivity distribution. Based on the coupling simulation, 16-electrode ECT sensors are recommended to achieve good image quality.
WOS标题词Science & Technology ; Technology
类目[WOS]Engineering, Multidisciplinary ; Instruments & Instrumentation
研究领域[WOS]Engineering ; Instruments & Instrumentation
关键词[WOS]IMAGE-RECONSTRUCTION ALGORITHM ; ELECTRODES
收录类别SCI
语种英语
WOS记录号WOS:000378821600005
内容类型期刊论文
源URL[http://ir.etp.ac.cn/handle/311046/112452]  
专题工程热物理研究所_中国科学院工程热物理所(论文库)_期刊论文(SCI)
作者单位1.Chinese Acad Sci, Inst Engn Thermophys, Beijing 100190, Peoples R China
2.Univ Manchester, Sch Elect & Elect Engn, Manchester M13 9PL, Lancs, England
推荐引用方式
GB/T 7714
Ye, Jiamin,Wang, Haigang,Yang, Wuqiang. Evaluation of electrical capacitance tomography sensor based on the coupling of fluid field and electrostatic field[J]. MEASUREMENT SCIENCE AND TECHNOLOGY,2016,27(7):1-13.
APA Ye, Jiamin,Wang, Haigang,&Yang, Wuqiang.(2016).Evaluation of electrical capacitance tomography sensor based on the coupling of fluid field and electrostatic field.MEASUREMENT SCIENCE AND TECHNOLOGY,27(7),1-13.
MLA Ye, Jiamin,et al."Evaluation of electrical capacitance tomography sensor based on the coupling of fluid field and electrostatic field".MEASUREMENT SCIENCE AND TECHNOLOGY 27.7(2016):1-13.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace