中文摘要电机电流信号特征分析(MCSA)是诊断鼠笼电机早期转子断条故障的常用方法。当电机在时变转速状态下运行时,转速和滑差连续变化,定子电流表现为非平稳信号,MCSA不再有效。本文提出一种鼠笼电机时变转速运行状态下的早期转子断条故障诊断新方法。该方法的核心是对定子电流Park矢量模平方信号作离散小波变换,然后根据转子断条故障特征频率2sf在转速连续变化期间的波形演变图谱以及小波能量变化判断故障发生与否。在3k W电机实验台上对所提出的方法进行实验验证,实验结果证实了所提方法的有效性。
英文摘要Motor current signature analysis (MCSA) has been successfully used in squirrel cage motor for the diagnosis of incipient broken rotor bar defect. However, when the motor operates in time-varying rotating speed condition, the method fails as the rotating speed and slip vary, thus, the stator current is characterized as a non-stationary signal. This paper proposes a novel fault diagnosis method for the incipient broken rotor bar of squirrel cage motor in time-varying rotating speed operation condition. The core of the method is to conduct discrete wavelet transformation on the 3 phase stator current Park's vector modulus square signal; and according to the waveform evolution spectrum of broken rotor bar fault frequency 2sf characteristic pattern and the wavelet energy changing during the speed continuous variation, it is judged if the broken rotor bar defect occurs. The experiment verification was performed on a 3kw motor experiment test bench; the experiment results prove the effectiveness of the proposed method. 
收录类别EI ; CSCD
语种中文
CSCD记录号CSCD:5708765
内容类型期刊论文
源URL[http://ir.sia.cn/handle/173321/18720]  
专题沈阳自动化研究所_信息服务与智能控制技术研究室
推荐引用方式
GB/T 7714
贾朱植,杨理践,祝洪宇,等. 时变转速运行状态下鼠笼电机转子断条故障诊断[J]. 仪器仪表学报,2016,37(4):834-842.
APA 贾朱植,杨理践,祝洪宇,&宋向金.(2016).时变转速运行状态下鼠笼电机转子断条故障诊断.仪器仪表学报,37(4),834-842.
MLA 贾朱植,et al."时变转速运行状态下鼠笼电机转子断条故障诊断".仪器仪表学报 37.4(2016):834-842.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace