通讯作者Xie Chengke, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800, China. ; Chen Ming, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800, China. ; Yang Baoxi, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800, China. ; Huang Huijie, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800, China.
中文摘要在以准分子激光为光源的步进扫描投影光刻机中,为了精确控制曝光剂量,需要用能量探测器实时、精确地监测单个激光脉冲的能量。研制了一种主要由聚光镜、积分棒、特殊晶体、滤光片、光电探测器和信号处理电路组成的准分子激光脉冲能量探测器;提出采用二阶有源低通滤波电路对窄脉冲信号进行整形处理以降低后续信号处理的难度;搭建测试装置对所研制的能量探测器进行了性能测试。测试结果表明,能量探测器输出的脉冲信号时间参数的实测值与设计值的相对误差约为3%,且其响应时间满足4 kHz高重频的应用要求;采用双光束比对法消除准分子激光单个脉冲能量波动对测试结果的影响,得到能量探测器的测量重复性为0.26%,在入射光束脉冲能量为0.1~1 muJ的动态范围内具有良好线性,其线性拟合方程为V=0.59841 E-0.01508,相应的线性相关系数R~2= 99.976%。测试结果证明二阶有源低通滤波电路可以实现窄脉冲信号整形;设计的能量探测器具有良好的重复性和线性,可用于光刻机中高重频准分子激光单个脉冲能量的精确测量。
英文摘要In step and scan lithographic tools whose laser sources are excimer lasers, an energy detector is needed to monitor excimer laser pulse energy in real-time and accurately so as to realize precise exposure dose control. An energy detector, which is composed by focusing lens, an integration rod, a special crystal, a filter, a photodiode and a signal processing circuit, is designed. Specially, the second-order active low-pass filter is used for narrow pulse shaping so as to reduce the difficulty of the signal processing circuit. Also, an experimental setup is designed to testing the performances of the energy detector. The results show that the relative error between the measured value and the designed value of the shaped pulse for the energy detector is about 3%, and the response time of the energy detector can meet the application of pulse energy measurement with pulse's repetition rate up to 4 kHz. Secondly, with a double-beam ratiometric method which is used to remove excimer laser pulse energy fluctuation, the performances of the energy detector are tested; the energy detector's repeatability is 0.26%; within a dynamic range of pulse energy from 0.1 muJ to 1 muJ per pulse, the linear fit is V=0.59841E-0.01508 and R~2=99.976%. Experimental results prove that the second-order active low-pass filter can be used for pulse shaping; the repeatability and the linearity of the designed energy detector are perfect, and the energy detector can be used to accurately measure the energy of high repetition rate pulse for excimer lasers in lithographic tools.
收录类别EI
原文出处http://www.opticsjournal.net
语种中文
内容类型期刊论文
版本出版稿
源URL[http://ir.siom.ac.cn/handle/181231/14178]  
专题上海光学精密机械研究所_信息光学与光电技术实验室
作者单位1.谢承科, 中国科学院上海光学精密机械研究所, 上海 201800, 中国.
2.陈明, 中国科学院上海光学精密机械研究所, 上海 201800, 中国.
3.杨宝喜, 中国科学院上海光学精密机械研究所, 上海 201800, 中国.
4.黄惠杰, 中国科学院上海光学精密机械研究所, 上海 201800, 中国.
推荐引用方式
GB/T 7714
谢承科,陈明,杨宝喜,等. 准分子激光脉冲能量探测器的设计与性能测试[J]. 中国激光,2015,42(1):102006.
APA 谢承科,陈明,杨宝喜,&黄惠杰.(2015).准分子激光脉冲能量探测器的设计与性能测试.中国激光,42(1),102006.
MLA 谢承科,et al."准分子激光脉冲能量探测器的设计与性能测试".中国激光 42.1(2015):102006.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace