Determination criterion of defrosting condition for variable refrigerant flow air conditioning system | |
Tu, Qiu1,3![]() | |
刊名 | energy and buildings
![]() |
2012-05-01 | |
卷号 | 48页码:61-70 |
关键词 | Defrosting Defrosting condition Condensation temperature Defrosting cycle Coil temperature |
英文摘要 | the disadvantage of the defrosting determination criterion of time-coil temperature was theoretically analyzed and experimentally verified. considering the different characteristics of variable refrigerant flow air conditioning system (vrf ac) from the common air conditioners, the defrosting criterion model of time-coil temperature-condensation temperature has been built. in this model, there exist four temperature regions based on different frosting characteristics at different ambient temperatures, i.e., t-ao(degrees c) is an element of (-infinity, -9], (-9, 0], (0, 4], (4, 21]. the relations between the defrosting judgment temperatures and ambient temperatures have been determined by experiments. and the minimum defrosting cycle when t-ao(degrees c) is an element of (-9, 21] and t-ao(degrees c) is an element of (-infinity, -9] were respectively determined to be 60 min and 90 min by experiments. moreover, the defrosting accumulative coefficient, the defrosting judgment time constant and the restriction of the condensation temperature have been introduced into the model. thus the complete criterion model can avoid delayed and premature defrosting, even false defrosting and inaccessible defrosting. a large number of experiments have verified the feasibility of the model. (c) 2012 elsevier b.v. all rights reserved. |
WOS标题词 | science & technology ; technology |
类目[WOS] | construction & building technology ; energy & fuels ; engineering, civil |
研究领域[WOS] | construction & building technology ; energy & fuels ; engineering |
关键词[WOS] | source heat-pump ; reverse-cycle defrost ; performance |
收录类别 | SCI |
语种 | 英语 |
WOS记录号 | WOS:000302669300007 |
内容类型 | 期刊论文 |
源URL | [http://ir.giec.ac.cn/handle/344007/10189] ![]() |
专题 | 中国科学院广州能源研究所 |
作者单位 | 1.Chinese Acad Sci, Guangzhou Inst Energy Convers, Guangzhou 510640, Guangdong, Peoples R China 2.Haier Air Conditioning Elect Co LTD, Qingdao 266510, Peoples R China 3.Chinese Acad Sci, Key Lab Renewable Energy & Gas Hydrate, Guangzhou 510640, Guangdong, Peoples R China |
推荐引用方式 GB/T 7714 | Tu, Qiu,Xu, Jingqiang,Feng, Yuhai,et al. Determination criterion of defrosting condition for variable refrigerant flow air conditioning system[J]. energy and buildings,2012,48:61-70. |
APA | Tu, Qiu,Xu, Jingqiang,Feng, Yuhai,Mao, Shoubo,Guo, Defang,&He, Jianqi.(2012).Determination criterion of defrosting condition for variable refrigerant flow air conditioning system.energy and buildings,48,61-70. |
MLA | Tu, Qiu,et al."Determination criterion of defrosting condition for variable refrigerant flow air conditioning system".energy and buildings 48(2012):61-70. |