Singlet Oxygen Phosphorescence Lifetime Imaging Based on a Fluorescence Lifetime Imaging Microscope
Tian, Wenming1; Deng, Liezheng1; Jin, Shengye1; Yang, Heping1; Cui, Rongrong1; Zhang, Qing2; Shi, Wenbo1; Zhang, Chunlei2; Yuan, Xiaolin2; Sha, Guohe1
刊名journal of physical chemistry a
2015-04-09
卷号119期号:14页码:3393-3399
英文摘要the feasibility of singlet oxygen phosphorescence (sop) lifetime imaging microscope was studied on a modified fluorescence lifetime imaging microscope (flim). sop results from the infrared radiative transition of o-2(a(1)delta(g) -> x-3 sigma(-)(g)) and o-2(a(1)delta(g)) was produced in a c-60 powder sample via photosensitization process. to capture the very weak sop signal, a dichroic mirror was placed between the objective and tube lens of the flim and used to divide the luminescence returning from the sample into two beams: the reflected sop beam and the transmitted photoluminescence of c-60 (c-60-pl) beam. the c-60-pl beam entered the scanner of the flim and followed the normal optical path of the flim, while the sop steered clear, of the scanner and directly entered a finely designed sop detection channel confocal c-60-pl images and nonconfocal sop images were then simultaneously obtained by using laser scanning mode. experimental results show that (1) under laser scanning mode, the obstacle to confocal sop imaging is the infrared incompatible scanner, which can be solved by using an infrared compatible scanner. confocal sop imaging is also expected to be realized under stage scanning mode when the laser beam is parked and meanwhile a pinhole is added into the sop detection channel. (2) a great challenge to sop imaging is its extraordinarily long imaging time, and selecting only a few interesting points from fluorescence images to measure their sop time-dependent traces may be a correct compromise.
WOS标题词science & technology ; physical sciences
类目[WOS]chemistry, physical ; physics, atomic, molecular & chemical
研究领域[WOS]chemistry ; physics
关键词[WOS]optical-detection ; cell ; photoluminescence ; diffusion ; resolution ; polymers ; images ; c-60 ; c60
收录类别SCI
语种英语
WOS记录号WOS:000352823100010
公开日期2016-05-09
内容类型期刊论文
源URL[http://cas-ir.dicp.ac.cn/handle/321008/146164]  
专题大连化学物理研究所_中国科学院大连化学物理研究所
作者单位1.Chinese Acad Sci, Dalian Inst Chem Phys, State Key Lab Mol React Dynam, Dalian 116023, Liaoning, Peoples R China
2.Dalian Univ, Affiliated Zhongshan Hosp, Res Ctr, Dalian 116001, Liaoning, Peoples R China
推荐引用方式
GB/T 7714
Tian, Wenming,Deng, Liezheng,Jin, Shengye,et al. Singlet Oxygen Phosphorescence Lifetime Imaging Based on a Fluorescence Lifetime Imaging Microscope[J]. journal of physical chemistry a,2015,119(14):3393-3399.
APA Tian, Wenming.,Deng, Liezheng.,Jin, Shengye.,Yang, Heping.,Cui, Rongrong.,...&Sha, Guohe.(2015).Singlet Oxygen Phosphorescence Lifetime Imaging Based on a Fluorescence Lifetime Imaging Microscope.journal of physical chemistry a,119(14),3393-3399.
MLA Tian, Wenming,et al."Singlet Oxygen Phosphorescence Lifetime Imaging Based on a Fluorescence Lifetime Imaging Microscope".journal of physical chemistry a 119.14(2015):3393-3399.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace