CORC  > 遥感与数字地球研究所  > SCI/EI期刊论文  > 期刊论文
In-Flight Radiometric Calibration for ZY-3 Satellite Multispectral Sensor by Modified Reflectance-Based Method
Han Jie1; Xie Yong1; Gu Xing-fa1; Yu Tao1; Liu Qi-yue1; Gao Rong-jun1
刊名SPECTROSCOPY AND SPECTRAL ANALYSIS
2015
卷号35期号:3页码:305-326
关键词ZY-3 satellite Multispectral sensor Artificial target Radiometric calibration
通讯作者Xie, Y (reprint author), Chinese Acad Sci, State Key Lab Remote Sensing Sci, Inst Remote Sensing & Digital Earth, Beijing 100105, Peoples R China.
英文摘要Through integrating multi-spectral sensor characteristics of ZY-3 satellite, a modified reflectance-based method is proposed and used to achieve ZY-3 satellite multispectral sensor in-flight radiometric calibration. This method chooses level 1A image as data source and establishes geometric model to get an accurate observation geometric parameters at calibration site according to the information provided in image auxiliary documentation, which can reduce the influences on the calibration accuracy from image resampling and observation geometry errors. We use two-point and multi-points methods to calculate the absolute radiometric calibration coefficients of ZY-3 satellite multispectral sensor based on the large campaign at Dongying city, Shan Dong province. Compared with ZY-3 official calibration coefficients, multi-points method has higher accuracy than two-point method. Through analyzing the dispersion between each calibration point and the fitting line, we find that the residual error of water calibration site is larger than others, which of green band is approximately 67.39%. Treating water calibration site as an error, we filter it out using 95.4% confidence level as standard and recalculate the calibration coefficients with multi-points method. The final calibration coefficients show that the relative differences of the first three bands are less than 2% and the last band is less than 5%, which manifests that the proposed radiometric calibration method can obtain accurate and reliable calibration coefficients and is useful for other similar satellites in future.
研究领域[WOS]Spectroscopy
收录类别SCI ; EI
语种中文
WOS记录号WOS:000351025600055
内容类型期刊论文
源URL[http://ir.ceode.ac.cn/handle/183411/38263]  
专题遥感与数字地球研究所_SCI/EI期刊论文_期刊论文
作者单位1.[Han Jie
2.Xie Yong
3.Gu Xing-fa
4.Yu Tao
5.Liu Qi-yue
6.Gao Rong-jun] Chinese Acad Sci, State Key Lab Remote Sensing Sci, Inst Remote Sensing & Digital Earth, Beijing 100105, Peoples R China
7.[Han Jie
8.Gao Rong-jun] Univ Chinese Acad Sci, Beijing 100049, Peoples R China
9.[Han Jie
10.Xie Yong
推荐引用方式
GB/T 7714
Han Jie,Xie Yong,Gu Xing-fa,et al. In-Flight Radiometric Calibration for ZY-3 Satellite Multispectral Sensor by Modified Reflectance-Based Method[J]. SPECTROSCOPY AND SPECTRAL ANALYSIS,2015,35(3):305-326.
APA Han Jie,Xie Yong,Gu Xing-fa,Yu Tao,Liu Qi-yue,&Gao Rong-jun.(2015).In-Flight Radiometric Calibration for ZY-3 Satellite Multispectral Sensor by Modified Reflectance-Based Method.SPECTROSCOPY AND SPECTRAL ANALYSIS,35(3),305-326.
MLA Han Jie,et al."In-Flight Radiometric Calibration for ZY-3 Satellite Multispectral Sensor by Modified Reflectance-Based Method".SPECTROSCOPY AND SPECTRAL ANALYSIS 35.3(2015):305-326.
个性服务
查看访问统计
相关权益政策
暂无数据
收藏/分享
所有评论 (0)
暂无评论
 

除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。


©版权所有 ©2017 CSpace - Powered by CSpace