Temperature effect on RPC performance in the ARGO-YBJ experiment | |
ARGO-YBJ Collaboration | |
刊名 | NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT |
2009 | |
卷号 | 608期号:2页码:#REF! |
关键词 | RPC Time resolution Efficiency Telescope |
通讯作者 | Wu, CY (reprint author), Chinese Acad Sci, Inst High Energy Phys, Key Lab Particle Astrophy, POB 918, Beijing 100049, Peoples R China. |
英文摘要 | The ARGO-YBJ experiment has been taking data for nearly 2 years. In order to monitor continuously the performance of the Resistive Plate Chamber detectors and to study the daily temperature effects on the detector performance, a cosmic ray muon telescope was setup near the carpet detector array in the ARGO-YBJ laboratory. Based on the measurements performed using this telescope, it is found that, at the actual operating voltage of 7.2kV, the temperature effect on the RPC time resolution is about 0.04ns/degrees C and on the particle detection efficiency is about 0.03%/degrees C. Based on these figures we conclude that the environmental effects do not affect substantially the angular resolution of the ARGO-YBJ detector. (C) 2009 Elsevier B.V. All rights reserved. |
学科主题 | Instruments & Instrumentation; Nuclear Science & Technology; Physics; Spectroscopy |
类目[WOS] | Instruments & Instrumentation ; Nuclear Science & Technology ; Physics, Particles & Fields ; Spectroscopy |
收录类别 | SCI |
WOS记录号 | WOS:000270326800004 |
公开日期 | 2016-05-03 |
内容类型 | 期刊论文 |
源URL | [http://ir.ihep.ac.cn/handle/311005/227174] |
专题 | 高能物理研究所_粒子天体物理中心 |
推荐引用方式 GB/T 7714 | ARGO-YBJ Collaboration. Temperature effect on RPC performance in the ARGO-YBJ experiment[J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT,2009,608(2):#REF!. |
APA | ARGO-YBJ Collaboration.(2009).Temperature effect on RPC performance in the ARGO-YBJ experiment.NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT,608(2),#REF!. |
MLA | ARGO-YBJ Collaboration."Temperature effect on RPC performance in the ARGO-YBJ experiment".NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT 608.2(2009):#REF!. |
个性服务 |
查看访问统计 |
相关权益政策 |
暂无数据 |
收藏/分享 |
除非特别说明,本系统中所有内容都受版权保护,并保留所有权利。
修改评论