Pilot testing of dissolved air flotation (DAF) in a highly effective coagulation-flocculation integrated (FRD) system | |
Wang, YL; Guo, JL; Tang, HX | |
刊名 | JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING |
2002 | |
卷号 | 37期号:1页码:95-111 |
关键词 | coagulation-flocculation integrated (FRD) system dissolved air flotation (DAF) hydraulic parameters polyaluminium chloride |
英文摘要 | Factors of pretreatment coagulation/flocculation units were studied using raw water of low temperature and low turbidity. Aluminum sulfate (AS) and selected polyaluminium chlorides (PACls) were all effective in the DAF process when used under favorable conditions of coagulant addition, coagulation, flocculation and flotation units. Compared with the AS coagulant, PACls, at lower dosage, could give the same effective performance even with shorter coagulation/flocculation time or lower recycle ratio during the treatment of cold water. This is attributed to the higher-charged polymeric Al species, and the lower hydrophilic and more compact flocculated flocs of PACl coagulant. Based on results of pilot experiments, the goal of FRD system can be achieved by combining a DAF heterocoagulation reactor with PACl coagulant (F), an efficient flocculation reactor (R), as well as an economical auto-dosing system (D). |
研究领域[WOS] | Engineering ; Environmental Sciences & Ecology |
WOS记录号 | WOS:000173750500009 |
内容类型 | 期刊论文 |
源URL | [http://ir.rcees.ac.cn/handle/311016/23935] |
专题 | 生态环境研究中心_环境水质学国家重点实验室 |
推荐引用方式 GB/T 7714 | Wang, YL,Guo, JL,Tang, HX. Pilot testing of dissolved air flotation (DAF) in a highly effective coagulation-flocculation integrated (FRD) system[J]. JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING,2002,37(1):95-111. |
APA | Wang, YL,Guo, JL,&Tang, HX.(2002).Pilot testing of dissolved air flotation (DAF) in a highly effective coagulation-flocculation integrated (FRD) system.JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING,37(1),95-111. |